Product Description
\ FEATURES \
1. High quality and high permeability silicon steel with a multi-stage stepping process leads to low no-load loss. |
2. The surface adopting nano paint self-leveling process leads to low noise. |
3. Strong waterproof and short-circuit resistance, strong overload capacity, good electrical performance, safety, and reliability. |
4. Through the simulation analysis of the electric field, temperature field, and magnetic field, CEEG is the first company in China to pass KEMA's E2, C2, and F1 tests. |
5. The product can adopt a dual-mode structure scheme to meet the needs of different customer groups. |
6. Special intelligent transformer solutions and big data cloud diagnosis technology are adopted to be online from time to time. |
Product Parameters
SCB 10-100~2500/10 |
Rated High Voltage:10(10.5,11,6.6,6.3,6)kV Connection Symbol:Dyn11/Yyn0 |
Nominal Low-voltage:0.4kV Tapping Range:±2×2.5% |
|
Model No. |
Uk % |
Air loss PO(W) |
Load loss
( 75ºC) PK(W) |
I0 ( %) |
LPA (AN ) dB |
Gauge m*n |
SIZE
L*B*H(mm) |
Enclosure Size
(top outging line)
(footing included) |
Enclosure Size
(side outging line)
(footing included) |
SC(B) 10-100/10 |
4 |
400 |
1371 |
0.7 |
42 |
550x 550 |
960x 750x804 |
1700x 1400x1600 |
1700x 1400x2200 |
SC(B) 10-125/10 |
4 |
470 |
1616 |
0.7 |
43 |
550x 550 |
9608750 x804 |
1700 x 1400x 1600 |
1700x 1400x2200 |
SC(B) 10-160/10 |
4 |
540 |
1860 |
0.7 |
43 |
550x 550 |
1040x 750¥859 |
1700x1400x 1600 |
1700x 1400x 2200 |
SC(B) 10-200/10 |
4 |
620 |
2209 |
0.7 |
43 |
550550 |
1040x750 x 874 |
1700x 1400x 1600 |
1700x 1400x 2200 |
SC(8) 10-250/10 |
4 |
720 |
2410 |
0.7 |
43 |
660¥660 |
1090x 860x 856 |
1700x1400 x 1600 |
1700x 1400¥2200 |
SC(B) 10-315/10 |
4 |
B80 |
3030 |
0.7 |
45 |
660x 660 |
1100 x 860 x923 |
1700 X 1400 x 1600 |
1700 x 14002200 |
SC(B) 10-400/10 |
4 |
980 |
3484 |
0.7 |
45 |
660x 660 |
1120 x 860x913 |
1700 x 1400x 1600 |
1700x1400 2200 |
SC (B) 10-500/10 |
4 |
1160 |
4260 |
0.6 |
46 |
680 x 660 |
1240x 860x953 |
1700x1400x 1600 |
1700x1400x2200 |
SC(B) 10-630/10 |
4 |
1340 |
5134 |
0.6 |
46 |
820¥660 |
1360 x 860x 956 |
1900 x1500x 1800 |
1900x1500 2200 |
SC (B) 10-630/10 |
6 |
1300 |
5200 |
0.6 |
48 |
820660 |
1380x 860x 938 |
1900x 1500x 1800 |
1900x 1500¥2200 |
SC(B) 10-800/10 |
6 |
1520 |
6020 |
0.5 |
49 |
820x 820 |
1450 x 1020x 993 |
1900 x 15001800 |
1900¥1500x 2200 |
SC(B)10-1000/10 |
6 |
1770 |
7090 |
0.4 |
50 |
820x B20 |
1510x 1020¥1058 |
1900 m 1500x 1800 |
19001500x 2200 |
SC (8) 10-1250/10 |
6 |
2090 |
8460 |
0.4 |
51 |
820x820 |
1530x 1020 x 1140 |
1900x1600x 1800 |
1900x 1600x2200 |
SC(B) 10-1600/10 |
6 |
2450 |
10240 |
0.3 |
51 |
820x 1070 |
1560x 1150x1223 |
2000x 1600x 2000 |
2000x1600x2200 |
SC (B) 10-2000/10 |
6 |
3050 |
12600 |
0.3 |
52 |
1070¥1070 |
1580x1150x1273 |
2000 x1600x 2000 |
20001600x2200 |
SC(B)10-2500/10 |
6 |
3600 |
15000 |
0.3 |
53 |
1070 x1070 |
1700x 1150x 1383 |
2200 x1600x 2200 |
2200x1600x2200 |
SC(B) 10-1600/10 |
8 |
2450 |
11263 |
0.3 |
51 |
820x 1070 |
1590 x1150 x 1198 |
2000 x1600x 2000 |
2000 x 1600x 2200 |
SC(B) 10-2000/10 |
8 |
3050 |
13882 |
0.3 |
52 |
1070x1070 |
1660x1150¥1298 |
2000x 1600x 2000 |
2000 x 1600x 2200 |
SC (B)10-2500/10 |
8 |
3600 |
16414 |
0.3 |
53 |
1070x1070 |
1720x 1150x 1493 |
2200x 1600x2200 |
2200x 1600x2200 |
\ CERTIFICATED & QUALIFIED \
SCB series cast resin dry-type transformers have reached the first-level energy efficiency standard of GB20052-2020, and won the 3C, PCCC energy-saving certification, ISO-9001, ISO-45001, and ISO-14001 certificates.
CEEG's cast resin dry-type power transformers have been widely adopted in key projects by customers from all over the world. For example, they have been chosen to serve in the Qingdao International Sailing Center, Beijing Urban sub-Center, Beijing Stadium the Skating Hall, Nanjing Metro, Shanghai EXPO Exhibition Center, etc.
Our Advantages
\ DESIGN & MANUFACTURE PROCESS \
Based on more than 30 years of design, manufacturing, and experimental experience in the transformer industry, CEEG has developed a set of advanced three-dimensional + parametric design software, which can realize automatic design, cost optimization, and simulation.
Fully considering the requirements of the national and industrial standards, ensuring the advantageous design of products.
The high-voltage winding conductor is wound with a high-quality conductor and reinforced with long and short-cut glass fiber felt. Poured by the advanced Heidrich vacuum pouring system under vacuum. Effectively restrain the occurrence of partial discharge, and the partial discharge is ≤ 5pc.
The low-voltage winding adopts a high-quality foil conductor and is wound on an automatic foil winding machine. The foil winding machine adopts the patented technology of foil wire hydraulic energy-saving tension crimping device, high-precision detection of ±0.5mm, and advanced argon arc welding technology, which plays a key role in ensuring the quality of coil winding.
The iron core adopts a high-quality high magnetic conductivity-oriented silicon steel sheet, a 45° full oblique step lapping process, and the surface adopts special moisture-proof and rust-proof coating, which effectively reduces the no-load current and noise level.
USE&PACKING
\ USE & INSTALLATION \
SERVICE CONDITIONS -
The installation site shall not be flooded by water, the altitude shall not exceed 1000m, and the ambient temperature shall not be higher than 40ºC. The relative humidity is 100%, and the environment is 40ºC to -25ºC (-25ºC requires an on-load tap changer and temperature controller).
PACKAGING & TRANSPORTATION - The products can be partially disassembled and transported (such as on-load tap changer, temperature controller, air cooling device, enclosure, etc. can be packaged separately) or packed as one piece in packaging boxes for transportation.
VISUAL INSPECTION BEFORE INSTALLATION - After opening the package, remove the protective device and check the external conditions, especially paying attention to the mechanical integrity of the coil and iron core, and the bolt fastening at the connection.
INSPECTION BEFORE OPERATION - Measure the DC resistance of high voltage and low voltage windings. Then check the grounding of the iron core to see whether the grounding is reliable and whether foreign matters are overlapping. Last to test the insulation resistance.
ENERGIZING - Before putting into operation, the transformer shall be put into trial operation under no-load, and the protection system shall be checked and adjusted after 3 times of impulse closing.
\ ABOUT CEEG \
3 INDUSTRIAL ZONES
4 FACTORIES
15 OVERSEAS BRANCHES
80+ GLOBAL MARKETS
THIS IS OUR DEVELOPMENT -
Headquartered in Nanjing, CEEG has always adhered to the core values of "foresight, innovation, and responsibility" since its establishment in 1990, focusing on production and manufacturing for more than 30 years. In years of development, CEEG has Integrated independent research and development, intelligent manufacturing, and smart marketing services.
OUR PARTNERS - Our products have been safely operating in major coal groups such as Shenhua Group, Anhui Tongling Mining Group, Pingdingshan Coal Industry Group, Jincheng Coal Industry Group, and Kaolain Group. Many well-known companies such as China Mobile, China Telecom, Inner Mongolia First Machinery, Inner Mongolia Pingzhuang Energy, and Jialing Motor also have established good partnerships with us. We also established long-term strategic cooperative relations with excellent enterprises all over the world, and our business partners include many great companies such as DuPont, Siemens, Hitachi Metals, and ABB. Our power transformers have been sold to over 80 countries and regions and got high recognition from customers overseas.