\ BRIEF INTRODUCTION \
ABOUT CEEG'S SCRBH SERIES - The amorphous alloy dry-type transformer adopts CEEG's unique semi-encapsulated three-phase three-column patented technology. The heat resistance level is as high as the H level, and the main insulating material is as high as the C level. It has a stronger overload capacity and short-circuits resistance. The main models include SCRBH15, SCRBH17, and SCRB19, and have all obtained energy-saving product certification, first-class energy efficiency certification, earthquake resistance report, and various test certificates.
Attributed to its great capacity and product features, SCRBH series amorphous alloy power transformers are professionally built for places with low power distribution utilization and high requirements for flammable, explosive, and fire prevention, such as cloud computing data centers, rural power grids, high-rise buildings, commercial centers, subways, airports, power plants, etc.
\ FEATURES \
1. Using a high-quality amorphous alloy Nomex strip, the no-load loss is reduced by about 70%.
2. The self-developed three-phase three-column structure covers a small area, and that ensures a much lighter-weight, easier installation.
3. Vibration model simulation analysis is used to reduce noise effectively.
4. Unique core suspension technology and end seal process to ensure low force on the core and low noise.
5. Adopt a unique semi-envelope structure type, strong dustproof ability, high product insulation performance
6. High mechanical strength, waterproof, and short circuit resistant.
\ CUTTING-EDGE CORE TECHNOLOGY \
WHY COULD CEEG'S SCRBH SERIES TRANSFORMERS BE WIDELY CHOSEN?
INDEPENDENT PRODUCTION LINE -
Focusing on power transformer manufacturing for more than 30 years and CEEG has built multiple independent production lines including the essential amorphous alloy iron core and also developed an exclusive professional manufacturing process.
EXCLUSIVE PATENTED TECHNOLOGY -
CEEG's core technology of three-phase and three-column has been awarded the National patent, guaranteeing a much light-weight, and promoted our power transformer's capacity to a higher level, gaining recognition from our customers all over the world.
ADVANCED MATERIALS DEVELOPED WITH
DUPONT NOMEX® - CEEG has built a solid cooperative relationship since 1999 with DuPont, the pioneer in the global power industry. With the technology developed in cooperation with DuPont, CEEG applied the advanced insulation systems to the power transformers manufacturing, ensuring a longer using life-span, and lower no-load loss.
GREATER CAPACITY OF MATERIALS - WHY DO WE USE AMORPHOUS ALLOY STRIPS?
THE COMPARISON BETWEEN AMORPHOUS ALLOY & ORIENTED ELECTRICAL STEEL
PARAMETER
|
CHARACTERISTICS |
AMORPHOUS ALLOY 2605SA1 |
ORIENTED ELECTRICAL STEEL |
MAGNETIC |
IRON LOSS W 13/50Hz(25ºC) SATURATION FLUX DENSITY(25ºC)
CURIE TEMPERATURE
|
0.1W/ kg
1.56T
415ºC |
0.86W / kg
2.0T
745ºC |
PHYSICAL |
DENSITY
LAMINATION FACTOR
RIGIDITY Hv
RESISTIVITY
|
7.18g / cm³
>85%
860
130μ Ωcm |
7.65g / cm³
>94%
180
45μ Ωcm |
SIZE |
BREADTH
THICKNESS
|
142, 170, 213mm
0.025mm |
~950mm
0.3mm |
OTHER |
ANNEAL
|
IN THE MAGNETIC FIELD / 380ºC~400ºC |
750ºC~850ºC |
\ CERTIFICATED & QUALIFIED \
SCRBH series amorphous alloy three-phase three-column dry-type power transformers have reached the GB 20052-2020, the first-level energy efficiency standard. And also gained energy-saving product certification, earthquake resistance report, and various test certificates, including the 3C, PCCC energy-saving, ISO-9001, ISO-45001, and ISO-14001 certificates.
CEEG's SCRBH series amorphous alloy dry-type power transformers have been widely adopted in key projects by customers from all over the world. Especially the mega construction projects led by the pioneer enterprises like China Telecom, China Mobile, China Unicom, Petrochemical Company Limited, Beijing General
Research Institute of Mining and Metallurgy, etc.
\ INTELLIGENT CLOUD COMPUTING PLATFORM \
EQUIPPED WITH CLOUD COMPUTING SMART MANAGEMENT SYSTEM
Facing the 5G era and aligning with the core value of "carbon peak" & "carbon neutrality", CEEG is positioned as a first-class energy efficiency management expert, always adhering to the mission of "maximizing the value of digital connections", and has built the first digital infrastructure based on transformer architecture in China -- Zhonghan loT Cloud Platform has implemented a series of world-first intelligent manufacturing projects in the transformer industry, and realized the intelligent manufacturing of transformer for the first time in the world.
With the intelligent cloud computing management system, CEEG ensures our customers could acquire the key data of transformers like the temperatures, currents, voltages, viberations, power harmonics, to finnally help with the real-time analysis of electric quality and trouble alarming on smartphones or persoal computers.
\ DESIGN & MANUFACTURE PROCESS \
Based on more than 30 years of design, manufacturing, and experimental experience in the transformer industry, CEEG has developed a set of advanced three-dimensional + parametric design software, which can realize automatic design, cost optimization, and simulation.
Fully considering the requirements of the national and industrial standards, ensuring the advantageous design of products.
The high-voltage winding conductor is wound with a high-quality conductor and reinforced with long and short-cut glass fiber felt. Poured by the advanced Heidrich vacuum pouring system under vacuum. Effectively restrain the occurrence of partial discharge, and the partial discharge is ≤ 5pc.
The low-voltage winding adopts a high-quality foil conductor and is wound on an automatic foil winding machine. The foil winding machine adopts the patented technology of foil wire hydraulic energy-saving tension crimping device, high-precision detection of ±0.5mm, and advanced argon arc welding technology, which plays a key role in ensuring the quality of coil winding.
The iron core adopts a high-quality high magnetic conductivity-oriented silicon steel sheet, a 45° full oblique step lapping process, and the surface adopts special moisture-proof and rust-proof coating, which effectively reduces the no-load current and noise level.
\ TESTING \
All products strictly control the production process and quality links, and conduct strict tests and inspections according to national standards and customized requirements before leaving the factory, including partial discharge inspection, lightning resistance and electric shock inspection, noise inspection, and other necessary inspection items. Advanced test and detection equipment and a perfect inspection and detection system ensure the high quality and high quality of products.
\ ACCESSORIES \
ENCLOSURE - The enclosure can be divided into indoor type and outdoor types. There are several observation windows on the enclosure and the enclosure can be sprayed with the color of the user's choice. The degree of protection of the enclosure is generally divided into IP20 or IP23. IP20 prevents the ingress of solid foreign objects larger than 12 mm and protects against accidental shocks. In addition to the functions of IP20, IP23 can also prevent water drops from entering within 60 degrees from the vertical, which is suitable for outdoor installation. The material of the enclosure is divided into ordinary steel sheet, plastic injection molding, stainless steel sheet, and aluminum alloy composite sheet.
TEMPERATURE CONTROLLER - All transformers are equipped with an overheating protection device. The overheat protection device detects and
controls the temperature of the transformer by means of a PT thermistor built into the low-voltage coil and outputs a digital signal via the RS232 / 485 communication interface. The device provides the following functions:
1/ During the operation of the transformer, the temperature value of the three-phase winding is displayed on a circuit.
2/ Display the temperature value of the hottest phase winding.
3/ Overtemperature alarm and overtemperature shutdown.
4/ Audible and visual alarm and fan start.
AIR COOLING DEVICE - The cooling mode of a dry-type transformer is divided into natural air cooling (AN) and forced air cooling (AF). Natural air cooling (AN) can continuously provide 120% of the rated power under normal operating conditions. Forced air cooling (AF) can increase capacity by 50% under normal operating conditions, which is suitable for all types of emergency overloads or intermittent overload operations. Due to the large increase in load losses and impedance resistance, forced air cooling (AF) is generally not recommended for long-term continuous overload operation.
COPPER BAR
- In general, the incoming and outgoing modes of the cables are divided into upper incoming & outgoing, lower incoming & outgoing, and side incoming & outgoing. For a transformer with rated power ≤ 200KVA, the conventional outgoing mode is still used, and the side outgoing line is connected by the user with a cable. If the rated power is ≥ 1600KVA, a, b, and c use double-row feeder lines with a spacing of 10 (1600200kva) or 12 (2500kVA). Since the zero line is at the top of the transformer, it is recommended that the transformer zero line still enters the switchgear from the top if the zero line is brought out from the bottom of the switchgear.
\ USE & INSTALLATION \
SERVICE CONDITIONS -
The installation site shall not be flooded by water, the altitude shall not exceed 1000m, and the ambient temperature shall not be higher than 40ºC. The relative humidity is 100%, and the environment is 40ºC to -25ºC (-25ºC requires an on-load tap changer and temperature controller).
The installation site shall be clean, free of conductive dust and corrosive gas, and have good ventilation or artificial ventilation conditions.
During product installation, it shall be 300mm away from walls and other obstacles, and there shall be a distance of 300mm between adjacent transformers. For distribution boxes and other places with limited installation space, the above distance can be adjusted appropriately.
PACKAGING & TRANSPORTATION - The products can be partially disassembled and transported (such as on-load tap changer, temperature controller, air cooling device, enclosure, etc. can be packaged separately) or packed as one piece in packaging boxes for transportation.
During the lifting process of the package, ropes shall be hung on sleepers at the four corners at the bottom of the package. Special lifting devices should be used to lift the products after the package is opened. It can be lifted 100mm - 150mm above the ground first, and then formally lifted after there is no abnormality.
During transportation, there shall be no upward and downward slope greater than 15° on the road. In order to ensure that the vehicle can bear the load evenly, the product center of gravity shall be located on the vertical centerline of the vehicle during loading. In order to prevent displacement and rollover during transportation, the long-axis direction of the product shall be consistent with the transportation direction, and the product shall be firmly bound on the vehicle.
VISUAL INSPECTION BEFORE INSTALLATION - After opening the package, remove the protective device and check the external conditions, especially paying attention to the mechanical integrity of the coil and iron core, and the bolt fastening at the connection.
After inspection, all fasteners, coils, and iron core pressing parts must be tightened in turn without any looseness.
Use dry compressed air or a clean cloth to clean the dust and dirt on the product.
When the storage time is long and there are water droplets or condensation on the transformer surface, it shall be dried until the insulation resistance of the coil is qualified.
INSPECTION BEFORE OPERATION - Measure the DC resistance of high voltage and low voltage windings. Then check the grounding of the iron core to see whether the grounding is reliable and whether foreign matters are overlapping. Last to test the insulation resistance.
ENERGIZING - Before putting into operation, the transformer shall be put into trial operation under no-load, and the protection system shall be checked and adjusted after 3 times of impulse closing.
When the product leaves the factory, the tap positions of voltage regulation at the high-voltage side are connected according to the rated position. Voltage adjustment is required during operation. The corresponding tap connection voltage is indicated on the nameplate (when there is no excitation voltage regulation), and it must be carried out when the transformer power supply is cut off.
\ ABOUT CEEG \ FOCUS ON POWER TRANSFORMERS MANUFACTURING FOR 30+ YEARS \
3 INDUSTRIAL ZONES
4 FACTORIES
15 OVERSEAS BRANCHES
80+ GLOBAL MARKETS
THIS IS OUR DEVELOPMENT -
Headquartered in Nanjing, CEEG has always been adhering to the core values of "foresight, innovation, and responsibility" since its establishment in 1990, focusing on production and manufacturing for more than 30 years. In years of development, CEEG has Integrated independent research and development, intelligent manufacturing, and smart marketing services.
OUR PRODUCT - Our technical team has continued to explore and innovate boldly, and has successfully developed nearly a hundred products including evaporative transformers, load centers, 35kV amorphous dry transformers, nuclear power transformers, slow harmonic transformers, high-temperature transformers; there are also outstanding players in market segments: traction transformers, variable current explosion-proof transformers, multiple Pulse wave phase shifting, wind power conversion, photovoltaic conversion, three-phase three-column amorphous conversion, intermediate test conversion, data center supercomputing mobile equipment, etc. Among them, the star products of the company are the green and energy-saving "amorphous alloy dry-type transformer", the technology-leading "epoxy cast dry-type transformer", and the safe and reliable "flameproof dry-type transformer for mine use and mobile substation". The technology applied to the production has won more than 70 patent technology qualification honors.
OUR PARTNERS - Our products have been safely operating in major coal groups such as Shenhua Group, Anhui Tongling Mining Group, Pingdingshan Coal Industry Group, Jincheng Coal Industry Group, and Kaolain Group. Many well-known companies such as China Mobile, China Telecom, Inner Mongolia First Machinery, Inner Mongolia Pingzhuang Energy, and Jialing Motor also have established good partnerships with us. We also established long-term strategic cooperative relations with excellent enterprises all over the world, and our business partners include many great companies such as DuPont, Siemens, Hitachi Metals, and ABB. Our power transformers have been sold to over 80 countries and regions and got high recognition from customers overseas.